ao smith water heater error code e05

Of course, there will be a solution which can be used for fixing this problem. You can hear the buzzing of the spark igniter. It does not store any personal data. See how to troubleshoot the flame failure, not enough, no hot water . So, check out the section again. Here are some error codes which can be learned. What you need to do is- attach the thermistor wires to the control board. I am still getting the error code. var dteNow = new Date(); Before inspecting for leaks, turn the unit off. We offer live virtual training on a selection of popular topics via Zoom. Either the thermopile doesnt cool down quickly or the pilot valve is stuck in an open position. Continue with Recommended Cookies. The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. The Solution Connections: Make sure the wiring is connected properly and isn't damaged. Take the sensor out and make sure that all the wires are properly connected. Related Parts Pages:A.O. Next, check the heating element for damage. You can either left-click on the link to open the manual in a new tab or right-click and save a copy directly on your computer. This chapter will discuss everything you need to know about the flashing light codes on AO Smith Water Heater. The cookies is used to store the user consent for the cookies in the category "Necessary". Solution: Check for blockage in the vents, the distance between the intake and exhaust terminals is per instructions, and remove if there is grease or dirt in the gas burner and fan motor. Related Price Pages:A.O. Clean the gas pipes properly if they are clogged and do not forget to turn off the valve before cleaning. Finally, turn on your water heater and you can see the error code is gone. Problem: Problem with the computer board. An example of data being processed may be a unique identifier stored in a cookie. If they come loose, tighten them up. A.O. how to fix the Pentair heater error codes problem, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. Problem: Miscommunication between the water heater and remote controller. How long does an A.O. Another sign that this is the issue is if the error code is blinking five times. The board replacement kit includes replacement yellow and blue wires with new connectors. Smith Water Heater, look no further! Trouble codes on the AO Smith Water Heater mean your water heater is not working properly. The cookie is used to store the user consent for the cookies in the category "Other. The wires connected to the stack flue sensor of the Pentair pool heater often loosen up automatically or get damaged. Read to know in details. The reason behind this is that the heater does not get enough water to heat up properly causing an imbalance in temperature. We will also tell you the solutions that will help you to fix the problem. Related Repair Pages:A.O. What does ECC code mean A.O. Debris and dirt could also be affecting the thermistor, so clean anything away and try again. Reasons Why There Is Water Leak Inside Refrigerator, Why Does My Air Conditioner Keep Freezing Up? Smith Signature 100 50-Gallons Tall 6-year Limited Warranty 4500-Watt Double Element Electric Water Heater Model # E6-50H45DV Find My Store for pricing and availability 2930 A.O. Comprehensive information about your new appliance - from getting started to cleaning and maintenance - with answers to frequently asked questions. It also causes the heater to shut down completely and display the E05 code on the Pentair heater. Leave a comment in the box below if you have any questions about the Pentair pool heater. The 4-chamber model of AO Smith Electric Tankless Water Heater only throws this error code. Now, you should be able to understand how these error codes work and what they mean. window.mc4wp.listeners.push( The national average is 67.5. } Takagi Water Heater Error Codes [Ultimate Guide], AO Smith Tankless Water Heater Stuck In Standby Mode [Solved! ECS40200 FPCR50260E GCNH30100 GCNH50100 GCV30 GCV40. Below, I will explain the meaning of status light codes and what steps you should take to stop the blinking light. CODE: 661, Four timesPROBLEM: Bypass valve fault (only model 540). Your AO Smith Electric Water Heater will throw the error codes E10, E11, E12, and E13 either for an open inlet temperature sensor or open thermistor. Smith Water Heaters, 500 Tennessee Waltz Parkway, Ashland City, TN 37015 USA, Tel: 1-800-433-2545 Website: www.aosmithwaterheaters.com Email: parts@hotwater.com A.O. Home | Sitemap | Blog| Privacy | Disclaimer | Contact| About. FIX: Is the water heater set for the right elevation? Dont need to worry about it. Tankless Water Heater Problems | Troubleshooting and Repair Tips, John Wood Tankless Error Codes | Troubleshooting Tips, Rheem Tankless Error Codes | Problems | Troubleshooting Guide, Takagi Error Codes | Troubleshooting Guide and Repair Tips, Rinnai Error Codes | Troubleshooting Rinnai Water Heaters, Noritz Error Codes Guide | Troubleshooting Noritz Water Heaters, How to Replace a Water Heater Dip Tube - DIY Installation Tips, How to Fix Water Hammer Problem | Troubleshooting Guide, Navien Water Heaters | Review and Buying Tips for 2023. See the symptoms of How to fix water hammer problem in pipes. CODE: 10 (101), Five timesPROBLEM: Warning for the "991" error code. Smith Signature 100 50-Gallon Tall 6-year Limited 40000-BTU Natural Gas Water Heater Model # G6N-UT5040NVR Find My Store })(); Anthony Barnes is the founder of Water Heater Hub and a second-generation plumber by profession. GCV40-200 GCV40-201 GCV50-200 GCV50-201 GCVH40L-200 GCVH40L-201. Then, use a flathead screwdriver to remove the nuts that hold the upper access panel in its place. Alternatively, you should check for any loose connections and damaged wires that could be behind this power loss. I recommend the factory setting or default of 120F (49C). Analytical cookies are used to understand how visitors interact with the website. Another sign that you are facing the same problem would be if the LED light is blinking once. CODE: 10 (101), Five times PROBLEM: Warning for the "991" error code. This prevents proper connectivity between the system and the sensor, causing the heater to shut down and display the E05 error code. Learn how to inspect and replace a water heater dip tube and solve the problems related to not enough hot water or sediment buildup. No, it's not. We also use third-party cookies that help us analyze and understand how you use this website. Wait for ten minutes to allow all the gas to clear out. For example, a bad thermostat, a bad computer board, and burn-out connectors that lead to the computer module are responsible for producing too much hot water. CODE: 39, 391, Two timesPROBLEM: Problem with the air-fuel ratio rod - AFR. What does E05 mean on a Pentair pool heater? Higher temperatures increase the risk of scalding, but even at 120F, hot water can If your AO Smith Electric Tankless Water Heater throws the error code E51 or E52, understand the user interface lost its connection with the control board. FIX: Check if the remote controller is the right type, also connections between the water heater and remote. Its very simple to reset your AO Smith Electric Water Heater by following the below instructions: ECC stands for Electro-chemical compression. If you choose a higher temperature, thermostatic mixing valves are particularly important to prevent scalding. Smith Water Heater Parts. Copyright. Smith NG water heater Commercial Shut down. Next, use the -inch open-end wrench and pull out the thermistor by turning it counter-clockwise. You should be able to find the settings in your water heaters manual, but if you are stuck, contact the support at AO Smith. How To Fix: First off, turn the gas control knob to the off position. This error code indicates that there is a problem with your water heaters computer board. FIX: Check for the proper settings on the computer board. scald in a matter of minutes. Your AO Smith Water Heater wont light up if there are electrical problems like the thermopile wires come loose. Can you hear a buzzing spark ignition from the burner or two clunk sounds from the gas valve? First off, relight the pilot following the steps I mentioned earlier to verify the status light is blinking 4 times. You can easily detect the exact problem of your water heater if you know the meaning of the flashing light code. Replace everything back into its place. This numerical code is telling you about the ignition failure. If you own a 540 model AO Smith tankless water heater, then this is an error code that may appear on your display screen. Solution: Check if the condensate drain is installed on the vent collar of the heater. Solution: See the error codes 331, 321, and 311. If the error code returns, I bet the sensor is at fault. From https://www.justanswer.com/ythiJustAnswer Customer from San Antonio, TX: AO Smith 50 gallon electric water heater giving error code e55 for water leak d. 4.6. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. It usually means that there is a problem with the bypass valve. We and our partners use cookies to Store and/or access information on a device. In other words, when the sensor senses the water temperature is too high, it will throw this error code. If the resistance of this part goes out of range, you must replace it. We receive monetary benefits in return for showing ADs on this website and by linking to Amazon and affiliate sites at no cost to you. A faulty code E06 on your AO Smith Water Heater stands for too hot water temperature. Open the control panel and make sure that the stack flue sensor is working properly. Summary of Contents for A.O. FIX: Check the connections between water heaters. Tanks, iCOMM Smart Connectivity allows you to get notifications and manage your water heater from your smartphone. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Fireplacehubs.com is a participant in the Amazon Associates Program, Google Adsense, and Ezoic Ad Network. (function() { AO Smith electric water heater keeps shutting off, e02 mike4500 Jun 18, 2019 M mike4500 Premium Member Joined Jun 18, 2019 Messages 5 Location NJ Jun 18, 2019 #1 Model Number 50 g Brand -brand- Age 1-5 years I have an AO Smith 50 gallon with the electronic display. Model HPX-66-DHPT120. I initially had to replace the lower element due to limescale. I unplugged the electronic panel, and the unit functions for a few hours when I turn off the breaker, wait several minutes then turn it on again. Examine the thermal regulator to see whether it is offering a proper performance or not. Revision 3 includes updated troubleshooting for error codes 4 and 6 and technical bulletins, Manual will be automatically added to "My Manuals", Error Code 3 - Pressure Switch Circuit Remains Closed, Error Code 4 - Pressure Switch Circuit Remains Open, Error Code 7,8,9 - Internal Control Failures, Error Code 10 - Flame Sensed out of Sequence, Error Code 11 - High Temperature Cutoff (Eco) Activated, Error Code 12 - Temperature Adjust Buttons Stuck Closed, Error Code 13 - Temperature Probe Open of Shorted, Error Code 14 - Resistor Wire Open or Shorted, Error Code 15 - Resistor Wire Resistance out of Tolerance, Technical Bulletin - Ignition and Flame Failure A-022-04 & S-021-04 Combined, Air Pressure Switch Circuit - Residential Power Vent/Power Direct Vent, Vent Termination Restrictor Usage for 40,000 Btu Power Vent Models, TB-A028-06 - A. O. Smith - FVIR Intelli-Vent Troubleshooting Chart, Normal Operating Sequence - Pressure Switch Circuit, Air Pressure Switch Circuit: Residential Power-Vent & Power-Direct-Vent Water Heaters, Air Pressure Switch Circuit: Cyclone Water Heater. Problem: Gas solenoid valve drive circuit failure. Finally, turn the power back to the unit and it will clear the error code. A.O. {{INUSING}}, The average cost per Mcf is ${{NATURALGASPRICE}} { Make sure that there are no parts of the sensor that require work. However, if it interrupts normal water heater operation, dont hesitate to call a plumber. Fixing the error as soon as it appears is important for the performance and longevity of the pool heater. CODE: 711, One timePROBLEM: Gas solenoid valve drive circuit failure. Look for the blockage in the vent system and ensure if the distance between the intake and exhaust is not too small. Brand: A.O. Understanding Noritz error codes and troubleshooting Noritz water heaters. Smith water heater? } listeners: [], But if you have to increase the water temperature, try to stay well below 150F (65C) so the high limit switch doesn't trip. Troubleshooting AO Smith condensing water heaters is similar to troubleshooting other brands and models. What does a thermal regulator do on a pool heater? While it may be igniting, its not keeping its flame and is going out before it can adequately warm up your water. The water heater is surely essential to support modern households, and we can make sure that people will look for the best water heater which can be used for their household needs. Fortunately, I broke down how you can replace the thermistor correctly in this section: Ao Smith Electric Water Heater Error Code E10-E13. These cookies will be stored in your browser only with your consent. A little more information.sometimes when I shut off power at the breaker, let is sit for a while and then turn the power back on, it will do it's diagnostic cycle (blinking green light) and then start flashing red (2 times). First, the pilot light wont come on until you try to light it up. No problems with the new one, plus it was much cheaper and lowes gave me a credit for the old one, not just a straight replacement, so I ended up with a lowes gift card for the difference. This time, it is referring to a problem with your exhaust thermistor. It may not display this or other websites correctly. CODE: 331, Two timesPROBLEM: Mixing thermistor failure. Smith INTELLI-VENT Page 1 INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters Printed in the USA - 0605 Part No. To bring your water heater to a normal operating state, you should replace the temperature sensor. FIX: Check for connection/breakage of wires, corrosion or frozen connectors, fan motor covered with the dust, burn marks on the computer board. Secondly, you must replace the gas control valve if the pilot valve gets stuck in an open position. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. Its important to note that the error codes we will be addressing in this guide are found on the 110, 510, 310, 240, 240 and 540 AO Smith tankless water heater models. The Water Heater Settings Hot, A, B, C, Very Hot Knob. Use the AO Smith code guide to find the main causes and solutions for the problems of the following models: 110, 310, 510, 240, 340, and 540 series, for safety, convenience, and great savings. ); Smith Signature 100 50-Gallons Tall 6-year Limited 40000-BTU Natural Gas Water Heater Model # G6N-T5040NVR Error Code 51, 55, 510, 551, Six times Problem: Abnormal gas solenoid valve. Defective Thermostat/Thermistor 3. advanced settings. Find the right water heater for your needs. First off, turn the gas control knob to the off position. He obtained his Bachelor of Science degree from the University Of Texas at El Paso. Besides, I will also walk you through the troubleshooting steps to clear those error messages. GCVL40-200 GCVL40-201 GNR40100 GNR50100 GPS-75 GPVH40100. I checked all the wires and didn't find any problems, frayed insulation, etc. ], Bosch Tankless Water Heater Maintenance [The Complete Guide], Bosch Tankless Water Heater Troubleshooting [A Complete Guide], Bosch Tankless Water Heater Error Codes [Ultimate Guide], Bosch Tankless Water Heater Wont Ignite [7 Easy Solutions]. Fix or replace the faulty parts, wires, or pipes as soon as you notice them. AO Smith Water Heater Error Code E02 [5 Easy Fixes] 1. I replaced it with another AO Smith model, but a more base model without the smart module option. Water Heaters - A.O.

Sun, Moon Rising Compatibility Calculator, Ruston High School Football State Championships, Grant Haag Net Worth, Articles A